Harmonic analysis, IEEE 519 studies, nuisance trip investigation and mitigation design, with Class A logging and root-cause analysis for industrial facilities.

Power quality problems are diagnosed by measurement, not by inspection. The failure modes that matter most tend to appear only under conditions nobody is watching — during an outage, on standby power, or at a load combination that occurs for an hour a week.

This is a defined specialisation for us rather than an occasional service. We run instrument-grade logging campaigns over weeks and months where the fault requires it, and we exclude candidate causes with evidence rather than by assertion.

What we do

Harmonic studies to IEEE 519. Voltage and current harmonics, THD and total demand distortion measured at the point of common coupling and assessed against the applicable limits, with Class A instrumentation.

Nuisance trip investigation. Distinguishing the currents that are routinely conflated — neutral return, zero-sequence and ground-return leakage, and harmonic distortion current — which present similarly at a breaker and have entirely different remedies.

Resonance and capacitor bank assessment. Switched power-factor-correction capacitors can form a parallel resonant circuit with supply transformer inductance and amplify specific harmonics. We assess detuning, inspect for the capacitor damage that accompanies resonance, and log with the bank energised and de-energised.

Standby generation and source impedance analysis. Generator impedance is typically three to four times that of the supply transformer, which amplifies existing distortion substantially when a facility transfers to standby. Facilities with heavy VFD loads are exposed to this by design.

Power logging and metering strategy. Where to meter, for how long, and what to measure — designed around the fault's actual behaviour rather than a standard package.

Mitigation design. Filters, reactors, detuning and distribution changes, specified against measured conditions.

Forensic power quality. Where the loss has already happened and the question is root cause — see forensic engineering.

Why measurement campaigns run long

Intermittent faults are not diagnosed in a site visit. On one recent investigation we ran three separate campaigns across roughly a year — zero-sequence branch-circuit logging across twelve channels, then Class A harmonic logging at three substation mains, then neutral and leakage-current surveys — because each campaign eliminated a theory and narrowed the next.

The alternative is guessing, and in power quality the intuitive fix is often the dangerous one. Raising a ground-fault pickup to stop nuisance trips silences the symptom and removes the protection the setting exists to provide.

Selected work

Forensic investigation — 24.9 kV campus facility — Ten months of recurring VFD failures traced to harmonic distortion exceeding IEEE 519 limits, with voltage THD reaching approximately 300% of nominal on standby power.

Metering programme — agricultural producer — Recurring 3,000 A breaker trips traced to a sustained zero-sequence imbalance averaging around 213 A, sourced from capacitive leakage in LED grow-light drivers.

Sectors

Industrial — mining and manufacturing · Power, energy and renewables · Healthcare and institutional

Talk to us about a power quality problem

Tell us what is failing and what you have measured so far.

Start a conversation